Valley Health System, Inpatient and Outpatient Facilities

Northern New Jersey

The New Valley Hospital, exterior

Overview

GBA’s commissioning work for Valley Health includes all phases of typical healthcare MEP/FP equipment and systems commissioning for major new construction projects, as well as renovations and fit-outs. The work represents the significant ongoing client relationship and includes multiple Valley Health System facilities in northern New Jersey, including inpatient and outpatient sites as well as a call center

Commissioning

Projects done by the GBA team at Valley Health facilities in New Jersey include:

  • The New Valley Hospital, Paramus. This major new replacement hospital on a 40-acre campus comprises about 910,000 square feet and 372 beds, plus a five-story parking garage. Departments include a Women’s and Children’s Pavilion, a Med/Surg Pavilion, an emergency department, diagnostic imaging, non-invasive cardiology, inpatient rehab, interventional medicine, a pharmacy, a clinical lab, and medical staff and facilities/support. Sustainable principles have been incorporated in the design, including green roofs and energy efficient infrastructure. LEED Gold is targeted.
  • The Valley Hospital, Robert and Audrey Luckow Pavilion satellite facility, Paramus. GBA has done multiple projects at the 128,000-square-foot Luckow Pavilion. These include the commissioning of extensive chiller plant renovations and an IVF laboratory (18,000 square feet), as well as a domestic water system survey. GBA is also providing ongoing engineering services, including miscellaneous retro-commissioning projects, systems/equipment optimization, performance testing, troubleshooting, operations and maintenance staff training, and project management.
  • 599 Valley Health Plaza, Paramus. A 58,000-square-foot project providing storage space, offices, a call center, a heating plant, an IDF closet, and security space.
  • 970 Linwood, Paramus. A 1,140-square-foot compounding pharmacy project. GBA also provided HVAC testing services at this facility.
  • 960 MacArthur, Mahwah. A 19,000-square-foot tenant fit-out project to create a new call center, as well as private offices, meeting/conference space, and a modular training space and break area.
  • Valley Medical Group, multiple locations. Outpatient sites commissioned by the GBA team include renovations at 1200 E. Ridgewood in Ridgewood and140 E. Ridgewood in Paramus. Facilities supported have included ophthalmology, a spine center, a walk-in center at Garden State Plaza shopping mall, and significant cooling tower upgrades at 140 E. Ridgewood. A project at 140 E. Paramus in Paramus created a 14,000-square-foot facility for clinical offices for a digestive medicine group.

View More Projects

Interested in learning more about how GBA can assist with your facility objectives? Our portfolio is a great place to start. 

Skyscraper board room

430 N. Michigan (Realtor Building)

A large-scale vertical expansion called on GBA's analytical, design, and commissioning skills.

Hallway with rehab equipment

Shirley Ryan AbilityLab, Pediatric & DayRehab Center

This outpatient center serves children and adults; GBA provided engineering design services for the adaptive reuse project.

Exterior of Todd Building, University of Kentucky

University of Kentucky, Lee T. Todd, Jr. Building

An ASHRAE Level 1 audit,  retro-commissioning, and a lab ventilation assessment improved sustainability.