Carle at the Fields, Ambulatory Surgery Center

Champaign, IL

Carle at the Fields, ASC, exterior

Overview

GBA provided mechanical, electrical, plumbing, fire protection, and medical gas engineering design services for the newly developed outpatient campus, encompassing a total of about 300,000 square feet of healthcare and office facilities. The Ambulatory Surgery Center is a 46,500-square-foot unit at the site.

MEP/FP/Medical Gas Design

Carle Foundation Hospital is developing Carle at the Fields, a new campus in southwestern Champaign that will allow consolidation of operations that were previously housed in scattered leased sites. The new Ambulatory Surgery Center reflects the area’s growing need for outpatient surgery services, as well as technical advances in outpatient procedures.

The Ambulatory Surgery Center includes eight operating rooms, one procedure room, three spaces set aside for future fit-out as procedure rooms, 26 prep/recovery bays, and on-site sterile processing. The building is engineered to accommodate a future expansion of another 10,000 square feet, with four additional operating rooms.

  • The engineering design includes fully redundant air-handling units serving the operating suites, safeguarding operations in critical spaces.
  • A new, magnetic-bearing air-cooled chiller plant serves both the surgery center and two associated medical office buildings. The project also includes a new boiler plant (three condensing boilers in a redundant system) and an oxygen farm (sited in the parking lot, with underground mains to the building).
  • Medical gases provided include medical air, vacuum, oxygen, and tanked gases (nitrogen, nitrous oxide, and carbon dioxide).
  • Operating room and procedure room pressure control and performance monitoring allow staff to ensure that critical spaces always comply with regulatory standards.
  • The snow melt system will make the site safer and more accessible year-round in the Midwestern climate.
1450X600
1450X600
1450X600
1450X600

View More Projects

Interested in learning more about how GBA can assist with your facility objectives? Our portfolio is a great place to start. 

430 N. Michigan (Realtor Building)

A large-scale vertical expansion called on GBA's analytical, design, and commissioning skills.

Shirley Ryan AbilityLab, Pediatric & DayRehab Center

This outpatient center serves children and adults; GBA provided engineering design services for the adaptive reuse project.

University of Kentucky, Lee T. Todd, Jr. Building

An ASHRAE Level 1 audit,  retro-commissioning, and a lab ventilation assessment improved sustainability.