Advocate Health, Administrative Facility

Suburban Chicago

Break room with tables and chairs in an office building

Overview

Formerly Advocate Health’s corporate offices, the single-story, 110,000-square-foot office building started its life as a warehouse. In this project, the building was remodeled to serve other administrative functions when the headquarters was relocated.

Renovation Design

The building, which serves 600 administrative employees, includes extensive areas of open offices, fully wired meeting rooms and training rooms, new bathrooms, and a large cafeteria. An existing data center remained in place and fully functional during construction.

  • As a result of a prior HVAC life cycle cost study by GBA, a number of small, old indoor air-handling units and small rooftop units were replaced with large, self-contained rooftop air conditioning units with variable air volume controls.
  • The long-term plan is to decommission the existing, outdated chiller plant and replace two existing steam boilers with condensing boilers.
  • The mechanical system includes a fully integrated DDC control system.
  • New domestic and fire protection water service was installed to eliminate an exterior underground fire protection loop that was failing.
  • GBA was tasked with minimizing HVAC equipment noise as much as possible, even in areas with open ceilings. Careful air system design, adequate isolation at the rooftop units, and the use of sound-attenuating materials ensured a quieter workspace.
  • In an added phase, our team designed an expansion to the existing data center’s uninterrupted power supply system, creating a 320 kVA system with 100% backup. The firm also replaced the data center’s cooling system with new computer room air handlers and a modular, 180-ton glycol chiller plant with cold-weather economizer.
  • A concept-level Basis of Design was provided for design/build contractors to bid a three-story addition to an existing two-story parking garage.

Photos courtesy of Horn Design

View More Projects

Interested in learning more about how GBA can assist with your facility objectives? Our portfolio is a great place to start. 

Skyscraper board room

430 N. Michigan (Realtor Building)

A large-scale vertical expansion called on GBA's analytical, design, and commissioning skills.

Hallway with rehab equipment

Shirley Ryan AbilityLab, Pediatric & DayRehab Center

This outpatient center serves children and adults; GBA provided engineering design services for the adaptive reuse project.

Exterior of Todd Building, University of Kentucky

University of Kentucky, Lee T. Todd, Jr. Building

An ASHRAE Level 1 audit,  retro-commissioning, and a lab ventilation assessment improved sustainability.