Electrical Commissioning Project engineer /Senior Project engineer 

EVANSTON, IL

Basic Functions and Minimum Responsibilities

Under direct supervision of Project Manager or other assigned supervisor and in collaboration with project team, the Electrical Commissioning Project Engineer is responsible for commissioning on multiple projects.

Technical

  • Working as a team member to solve complex problems in connection with engineering design and site installations (including special studies, analyses, testing and troubleshooting existing systems).
  • Able to perform field survey work and to obtain (at a minimum) amp, volt, power readings, minimum OA measurements, IAQ parameters, control set points, and rotational speed of equipment.
  • Has experience with, and understands operation of, HVAC systems and their supporting electrical infrastructure.
  • Prepares field observation reports and punch lists.
  • Prepares pre-functional, functional, and point-to-point checklists.
  • Prepares systems manuals and can produce accurate, well-written technical correspondence and reports.
  • Participates in the development of GBA’s standard technical procedures and master documents upon request.

Management

  • Critical items or problems must be brought to the attention of the supervisor in a timely manner (technical, budget, manpower communications, client/team politics, deadlines, etc.). Items involving potential errors/omissions or other legal exposure must be brought to the Project Manager and Principal-in-Charge within 24 hours.
  • Complete timecard within 24 hours of the end of each pay period.

Business Development

  • Ability to assist with the organization of marketing data.
  • Identifies potential opportunities and informs the Project Manager or Principal so that the opportunity can be explored.

Basic Qualifications

  • Bachelor’s degree in Electrical Engineering from an accredited university or equivalent experience.
  • Approximately three to seven years of experience.
  • Professional Engineer (PE) license or pursuing PE preferred.
  • Demonstrates basic level of knowledge of codes/standards, materials, details, and construction techniques.
  • Demonstrates basic knowledge of mechanical and architectural practice to the degree that our engineering efforts are integrated and coordinated with these other trades.

Professional Qualifications

  • Ability to communicate effectively with supervisors and peers to present recommendations/proposed solutions.
  • Conducts oneself in a professional manner (tactful, polite, etc.).
  • Willing to work during a variety of work hours, which will vary based on individual project requirements which may include nights, weekends, and holidays (with advance notice).
  • Accepts criticism in a positive way.
  • Able to follow directions.
  • Conscientiousness in carrying out assignments.
  • Operates as team player, volunteering to help co-workers and taking on other challenges, as appropriate.
  • Ability to understand and complete tasks with relative independence.
  • Ability to keep supervisors informed regarding project status, including changes/difficulties and schedule implications.
  • Encourages, initiates, and participates in training and development activities. Demonstrates practical knowledge of office standards, policies and procedures and assists in development of office standards, policies, and procedures.
  • Motivated to learn, asks questions, seeks a higher level of understanding of technical and management issues.
  • Active in professional and/or technical organizations.
  • Demonstrates leadership.

Apply Now!